Problem with comparison.
/Designs/Measuring_instruments/GeoMet01A/SW/PIC16F887/main.c |
---|
0,0 → 1,68 |
#include "main.h" |
#define LCD_ENABLE_PIN PIN_E0 //// |
#define LCD_RS_PIN PIN_E1 //// |
#define LCD_RW_PIN PIN_E2 //// |
#define LCD_DATA4 PIN_D4 //// |
#define LCD_DATA5 PIN_D5 //// |
#define LCD_DATA6 PIN_D6 //// |
#define LCD_DATA7 PIN_D7 |
#include <lcd.c> |
#include "../SHT25.h" |
#include "../LTS01.h" |
#include "./HMC5883L.h" |
#include <math.h> |
void main() |
{ |
float temp1, temp2, humidity; |
int16 i=0; |
setup_adc_ports(NO_ANALOGS|VSS_VDD); |
setup_adc(ADC_CLOCK_DIV_2); |
setup_spi(SPI_SS_DISABLED); |
setup_timer_0(RTCC_INTERNAL|RTCC_DIV_1); |
setup_timer_1(T1_DISABLED); |
setup_timer_2(T2_DISABLED,0,1); |
setup_ccp1(CCP_OFF); |
setup_comparator(NC_NC_NC_NC); // This device COMP currently not supported by the PICWizard |
setup_oscillator(OSC_8MHZ); |
printf("GeoMet01A\r\n"); |
printf("(c) Kaklik 2013\r\n"); |
printf("www.mlab.cz\r\n"); |
// Init the HMC5883L. Set Mode register for |
// continuous measurements. |
hmc5883l_write_reg(HMC5883L_CFG_A_REG, 0x18); // no average, maximal update range |
hmc5883l_write_reg(HMC5883L_CFG_B_REG, 0x00); // minimal range |
hmc5883l_write_reg(HMC5883L_MODE_REG, 0x00); |
lcd_init(); |
lcd_putc("(c) Kaklik 2013"); |
lcd_gotoxy(3,2); |
lcd_putc("www.mlab.cz"); |
Delay_ms(2000); |
lcd_init(); |
while (TRUE) |
{ |
lcd_gotoxy(1,1); |
temp1 = SHT25_get_temp(); |
humidity = SHT25_get_hum(); |
temp2= LTS01_get_temp(); |
hmc5883l_read_data(); |
printf(lcd_putc,"%f C %f \%%",temp1, humidity); |
lcd_gotoxy(1,2); |
printf(lcd_putc," %f C",temp2); |
printf("%ld %f %f %f ",i, temp1, humidity, temp2); |
printf("%Ld %Ld %Ld \n\r", compass.x, compass.y, compass.z); |
i++; |
Delay_ms(100); |
} |
} |