Rev 4393 Rev 4415
Line 40... Line 40...
40 print "External Voltage Measurement" 40 print "External Voltage Measurement"
41 guage.WriteFlashByte(64, 0, 7, 0x2) # Two Cells 41 guage.WriteFlashByte(64, 0, 7, 0x2) # Two Cells
42 print "Two Cells" 42 print "Two Cells"
43 guage.WriteFlashByte(64, 0, 4, 0x74) # 8 LED (1+7), Shift Register 43 guage.WriteFlashByte(64, 0, 4, 0x74) # 8 LED (1+7), Shift Register
44 print "LED" 44 print "LED"
45 guage.WriteFlashByte(104, 0, 14, 0x28) # Voltage Measurement Range 10240 mV 45 guage.WriteFlashByte(104, 0, 14, 0x25) # Voltage Measurement Range 9484 mV
46 guage.WriteFlashByte(104, 0, 15, 0x00) # 46 guage.WriteFlashByte(104, 0, 15, 0x0C) #
47 print "Voltage Measurement Range" 47 print "Voltage Measurement Range"
48 guage.WriteFlashByte(82, 0, 0, 0x0D) # Set initial cell capacity 3350 mAh 48 guage.WriteFlashByte(82, 0, 0, 0x0D) # Set initial cell capacity 3350 mAh
49 guage.WriteFlashByte(82, 0, 1, 0x16) # 49 guage.WriteFlashByte(82, 0, 1, 0x16) #
50 print "Initial cell capacity" 50 print "Initial cell capacity"
51 guage.WriteFlashByte(83, 0, 0, 0x20) # Set Chem ID 51 guage.WriteFlashByte(83, 0, 0, 0x20) # Set Chem ID