#!/usr/bin/python
# Python test script for MLAB ALTIMET01A sensor
import time
import datetime
import sys
import serial
from pymlab import config
#### Script Arguments ###############################################
if len(sys.argv) != 2:
sys.stderr.write("Invalid number of arguments.\n")
sys.stderr.write("Usage: %s #I2CPORT\n" % (sys.argv[0], ))
sys.exit(1)
port = eval(sys.argv[1])
#### Sensor Configuration ###########################################
cfg = config.Config(
i2c = {
"port": port,
},
bus = [
{
"type": "i2chub",
"address": 0x72,
"children": [
{"name": "altimet", "type": "altimet01" , "channel": 7, },
],
},
],
)
cfg.initialize()
gauge = cfg.get_device("altimet")
time.sleep(0.5)
#### Data Logging ###################################################
sys.stdout.write("ALTIMET data acquisition system started \n")
try:
while True:
gauge.route()
(t1, p1) = gauge.get_tp()
sys.stdout.write(" Temperature: %.2f Pressure: %d \n" % (t1, p1))
sys.stdout.flush()
# time.sleep(0.5)
except KeyboardInterrupt:
ser.close()
sys.exit(0)