Rev Age Author Path Log message Diff
3106 3983 d 3 h kaklik / vygenerovani QR kodu v modulech, ktere maji existujici soubor PrjInfo.txt Diff
2843 4087 d 2 h kaklik / zaznaw chyb na modulech a upravy SW z frantovejch. Diff
2439 4394 d 8 h kaklik /Modules/TDC/GP201A/ pridani obrazku modulu. Diff
2192 4640 d 5 h kaklik /Modules/TDC/GP201A/CAM_PROFI/ Diff
2191 4640 d 5 h kaklik /Modules/TDC/GP201A/CAM_PROFI/ Diff
2190 4640 d 5 h kaklik /Modules/TDC/GP201A/ marketingove upravy Diff
2189 4640 d 5 h kaklik /Modules/ pridani dat k USB verzi ANT modulu Diff
2188 4640 d 15 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ zvetseni mericiho rozsahu. Diff
2187 4641 d 10 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ pokusy se zmenou rozliseni. Diff
2186 4641 d 13 h kaklik /Modules/TDC/GP201A/SW/PCHost/ logovaci skript pro mereni. Diff
2185 4642 d 4 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ meri uz i v modu 1. Diff
2184 4643 d 3 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ Mereni v modu 1 nejak funguje pro oba kanaly, ale nefunguje vypocet vyslednych casu. Diff
2183 4643 d 4 h kaklik /Modules/TDC/GP201A/SW/ odstraneni nasledku toho, ze byly prohozene popisky v potisku. Diff
2182 4643 d 4 h kaklik /Modules/TDC/GP201A/ zjistilo se, ze v popiscich na tistaku byly prohozene STOP2 a STOP1_EN popisky v dosledku toho byl zmatek pri programovani. Diff
2181 4643 d 8 h kaklik /Modules/TDC/GP201A/SW/ Az na Mod 1 celkem funkci verze. V modu 1 nechyta stop impulzy na kanalu 2. Diff
2179 4646 d 8 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ naprogramovano cteni vstupu. Diff
2178 4647 d 6 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ Diff
2174 4649 d 5 h kaklik /Modules/TDC/GP201A/SCH/ vygenerovani noveho PDFka Diff
2165 4653 d 11 h kaklik /Modules/ synchronizace tistaku se schematem Diff
2164 4655 d 7 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ uz funguje mereni teploty Diff
2163 4655 d 14 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ nefunguje mereni teploty spolecne s mericim modem 2 Diff
2162 4656 d 3 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ verze s externim generatorem impulzu. Diff
2161 4656 d 3 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ Diff
2160 4656 d 4 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ vycisteni Diff
2159 4656 d 9 h kaklik / teplomer naportovan na novejsi PIC. Diff
2157 4656 d 13 h kaklik / aktualizace Diff
2142 4663 d 12 h kaklik / navrh modulu nizkosumoveho zesilovace. Diff
2015 4745 d 5 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ Diff
2014 4745 d 7 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ Diff
2013 4745 d 12 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ drobne upravy Diff
2012 4746 d 4 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ migrace na PIC16F887 Diff
2011 4746 d 5 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ posledni verze pred prechodem na PIC16F887 Diff
1980 4774 d 11 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ pokus o zprovozneni mericiho modu 1.
V tomto stavu ale asi nefunguje ani mereni teploty.
Diff
1967 4780 d 3 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ oprava chyby ve vypoctu casu a implementace mereni teploty. Diff
1966 4780 d 4 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ prvni implementace prepoctu na realne jednotky. Diff
1965 4780 d 7 h kaklik /Modules/TDC/GP201A/ implementace i posledni primitivy pro nastavovani registru Diff
1964 4780 d 7 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ prepsani cteni dat do puvodnich primitiv. Diff
1931 4799 d 3 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ testovani TDC Diff
1930 4799 d 8 h kaklik / preklad kodu Diff
1886 4837 d 4 h kakl /Modules/TDC/GP201A/SW/PICinterface/ Prvni verze, co neco meri. Diff