Rev Age Author Path Log message Diff
3106 4093 d 19 h kaklik / vygenerovani QR kodu v modulech, ktere maji existujici soubor PrjInfo.txt Diff
2843 4197 d 18 h kaklik / zaznaw chyb na modulech a upravy SW z frantovejch. Diff
2439 4505 d 0 h kaklik /Modules/TDC/GP201A/ pridani obrazku modulu. Diff
2192 4750 d 21 h kaklik /Modules/TDC/GP201A/CAM_PROFI/ Diff
2191 4750 d 21 h kaklik /Modules/TDC/GP201A/CAM_PROFI/ Diff
2190 4750 d 21 h kaklik /Modules/TDC/GP201A/ marketingove upravy Diff
2189 4750 d 21 h kaklik /Modules/ pridani dat k USB verzi ANT modulu Diff
2188 4751 d 6 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ zvetseni mericiho rozsahu. Diff
2187 4752 d 2 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ pokusy se zmenou rozliseni. Diff
2186 4752 d 5 h kaklik /Modules/TDC/GP201A/SW/PCHost/ logovaci skript pro mereni. Diff
2185 4752 d 20 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ meri uz i v modu 1. Diff
2184 4753 d 19 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ Mereni v modu 1 nejak funguje pro oba kanaly, ale nefunguje vypocet vyslednych casu. Diff
2183 4753 d 20 h kaklik /Modules/TDC/GP201A/SW/ odstraneni nasledku toho, ze byly prohozene popisky v potisku. Diff
2182 4753 d 20 h kaklik /Modules/TDC/GP201A/ zjistilo se, ze v popiscich na tistaku byly prohozene STOP2 a STOP1_EN popisky v dosledku toho byl zmatek pri programovani. Diff
2181 4754 d 0 h kaklik /Modules/TDC/GP201A/SW/ Az na Mod 1 celkem funkci verze. V modu 1 nechyta stop impulzy na kanalu 2. Diff
2179 4757 d 0 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ naprogramovano cteni vstupu. Diff
2178 4757 d 22 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ Diff
2174 4759 d 20 h kaklik /Modules/TDC/GP201A/SCH/ vygenerovani noveho PDFka Diff
2165 4764 d 3 h kaklik /Modules/ synchronizace tistaku se schematem Diff
2164 4765 d 23 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ uz funguje mereni teploty Diff
2163 4766 d 6 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ nefunguje mereni teploty spolecne s mericim modem 2 Diff
2162 4766 d 19 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ verze s externim generatorem impulzu. Diff
2161 4766 d 19 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ Diff
2160 4766 d 20 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ vycisteni Diff
2159 4767 d 1 h kaklik / teplomer naportovan na novejsi PIC. Diff
2157 4767 d 5 h kaklik / aktualizace Diff
2142 4774 d 4 h kaklik / navrh modulu nizkosumoveho zesilovace. Diff
2015 4855 d 21 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ Diff
2014 4855 d 23 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ Diff
2013 4856 d 4 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ drobne upravy Diff
2012 4856 d 20 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ migrace na PIC16F887 Diff
2011 4856 d 21 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ posledni verze pred prechodem na PIC16F887 Diff
1980 4885 d 3 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ pokus o zprovozneni mericiho modu 1.
V tomto stavu ale asi nefunguje ani mereni teploty.
Diff
1967 4890 d 19 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ oprava chyby ve vypoctu casu a implementace mereni teploty. Diff
1966 4890 d 20 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ prvni implementace prepoctu na realne jednotky. Diff
1965 4890 d 23 h kaklik /Modules/TDC/GP201A/ implementace i posledni primitivy pro nastavovani registru Diff
1964 4890 d 23 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ prepsani cteni dat do puvodnich primitiv. Diff
1931 4909 d 19 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ testovani TDC Diff
1930 4910 d 0 h kaklik / preklad kodu Diff
1886 4947 d 20 h kakl /Modules/TDC/GP201A/SW/PICinterface/ Prvni verze, co neco meri. Diff