←Prev12Next→ Show All
Rev Age Author Path Log message Diff Changes
2913 4223 d 3 h kaklik /Designs/Measuring_instruments/AWS01A/SW/ pridani druheho cidpa pro mereni vphkosti a teploty Diff
/Designs/Measuring_instruments/AWS01A/SW/SHT25.c
/Designs/Measuring_instruments/AWS01A/SW/SHT25.h
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/main.c
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/main.h
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/main.hex
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/main.pjt
/Designs/Measuring_instruments/AWS01A/SW/ds1820.c
2907 4223 d 19 h kaklik / uprava vypisu a vypocet rychlosti vetru. Diff
/Modules/HumanInterfaces/TOUCHBOARD01A/TODO.txt
/Designs/Measuring_instruments/AWS01A/SW/MPL115A1.c
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/main.c
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/main.hex
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/main.pjt
/Designs/Measuring_instruments/AWS01A/SW/SHT.c
2904 4223 d 22 h kaklik /Designs/Measuring_instruments/AWS01A/SW/PIC16F887/ uprava bootloaderu, aby nedaval ven hodiny Diff
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/bootloader887/bloader.PJT
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/bootloader887/bloader.h
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/bootloader887/bloader.hex
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/main.hex
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/main.pjt
2899 4225 d 17 h kaklik /Designs/Measuring_instruments/AWS01A/SW/PIC16F887/ Odkomentovani vycitani dat z barometru. Diff
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/main.c
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/main.hex
2898 4227 d 17 h kakl /Designs/Measuring_instruments/AWS01A/SW/PIC16F887/ ECHO ve Woknech pridava na konec radku mezeru. Diff
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/bootloader887/bloader.c
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/bootloader887/bloader.hex
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/common/bloader_defs.h
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/test_interrupt/main.c
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/test_interrupt/main.pjt
2897 4227 d 18 h kakl /Designs/Measuring_instruments/AWS01A/SW/PIC16F887/ Opet povoleny interrupty. Diff
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/bootloader887/bloader.c
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/main.c
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/main.hex
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/main.pjt
2896 4227 d 19 h kakl /Designs/Measuring_instruments/AWS01A/SW/PIC16F887/bootloader887/ Prepisovaly se NOPy na zacatku. Diff
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/bootloader887/bloader.PJT
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/bootloader887/bloader.c
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/bootloader887/bloader.hex
2858 4245 d 23 h kaklik /Designs/Measuring_instruments/AWS01A/SW/PIC16F887/ testovani na zarizeni v uniboxu Diff
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/main.c
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/main.hex
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/main.pjt
2848 4247 d 7 h kakl /Designs/Measuring_instruments/AWS01A/SW/PIC16F887/ Uprava skoku na preruseni.
V obsluze preruseni se zrejme nesmi delat relativni GOTO.
Diff
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/dbloader.c
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/bootloader887/bloader.PJT
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/bootloader887/bloader.c
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/bootloader887/bloader.hex
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/common/dbloader.h
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/main.c
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/main.h
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/main.hex
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/main.pjt
2847 4248 d 5 h kaklik /Designs/Measuring_instruments/ pridani informaci o heliu Diff
/Designs/Measuring_instruments/ABL01A/pdf/napln/Balonplyn79_15334.pdf
/Designs/Measuring_instruments/ABL01A/pdf/napln/Kartuse_s_heliem.png
/Designs/Measuring_instruments/ABL01A/pdf/napln/Linde_helium.pdf
/Designs/Measuring_instruments/ABL01A/pdf/napln/Redukcni_ventil.png
/Designs/Measuring_instruments/AWS01A/TODO.txt
2843 4249 d 16 h kaklik / zaznaw chyb na modulech a upravy SW z frantovejch. Diff
/Designs/Measuring_instruments/AWS01A/SW/AVR
/Designs/Measuring_instruments/AWS01A/SW/AVR/config.h
/Designs/Measuring_instruments/AWS01A/SW/AVR/sht11.c
/Designs/Measuring_instruments/AWS01A/SW/AVR/sht11.h
/Designs/Measuring_instruments/AWS01A/SW/SHT.h
/Designs/Measuring_instruments/AWS01A/pdf/Sensirion_Humidity_SHT1x_SHT7x_CRC_Calculation_V1.pdf
/Designs/Measuring_instruments/AWS01A/pdf/Sensirion_Humidity_SHTxx_Sample_Code_V2.07.pdf
/Modules/Sensors/IMU01A/TODO.txt
/Modules/Sensors/SHT25V01A/TODO.txt
/Modules/TDC/GP201A/pdf
/Modules/TDC/GP201A/pdf/H19.pdf
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/main.c
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/main.hex
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/main.pjt
/Modules/CommSerial/JTAGFT2232V02A/SCH_PCB/untitled.brd
/Modules/CommSerial/JTAGFT2232V02A/TODO.txt
/Modules/H_Bridge/DRV8835HB01A/PrjInfo.txt
/Modules/H_Bridge/DRV8835HB01A/SCH_PCB/untitled.brd
/Modules/H_Bridge/DRV8835HB01A/TODO.txt
/Modules/PowerSupply/LION1CELL01A/SCH_PCB/untitled.brd
/Modules/PowerSupply/LION1CELL01A/TODO.txt
/Modules/Sensors/IMU01A/SCH_PCB/untitled.brd
/Modules/Sensors/SHT25V01A/SCH_PCB/untitled.brd
2838 4252 d 19 h kaklik /Designs/Measuring_instruments/AWS01A/SW/PIC16F887/ fungujici cidla krome anemometru Diff
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/main.c
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/main.hex
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/main.pjt
2837 4252 d 21 h kaklik /Designs/Measuring_instruments/AWS01A/SW/ zlepseni presnosti cteni vlhkosti. Diff
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/main.c
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/main.hex
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/main.pjt
/Designs/Measuring_instruments/AWS01A/SW/SHT.c
2836 4252 d 23 h kaklik /Designs/Measuring_instruments/AWS01A/SW/ Diff
/Designs/Measuring_instruments/AWS01A/SW/SHT.c
/Designs/Measuring_instruments/AWS01A/SW/ds1820.c
2835 4253 d 0 h kaklik /Designs/Measuring_instruments/AWS01A/SW/PIC16F887/ zvysena adolnost proti adpojeni cidla Diff
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/main.c
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/main.hex
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/main.pjt
2834 4253 d 15 h kaklik /Designs/Measuring_instruments/AWS01A/SW/ uprava sw, aby byl odolny proti vypadku cidla. Diff
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/main.c
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/main.hex
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/main.pjt
/Designs/Measuring_instruments/AWS01A/SW/ds1820.c
2833 4253 d 16 h kaklik /Designs/Measuring_instruments/AWS01A/SW/PIC16F887/ Diff
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/main.hex
2831 4257 d 21 h kaklik /Designs/Measuring_instruments/AWS01A/ zapis nalezenych vad Diff
/Designs/Measuring_instruments/AWS01A/TODO.txt
2830 4257 d 21 h kakl /Designs/Measuring_instruments/AWS01A/SW/PIC16F887/test_interrupt/ Testovani interruptu s BootLoaderem. Diff
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/test_interrupt
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/test_interrupt/main.c
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/test_interrupt/main.h
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/test_interrupt/main.pjt
2829 4257 d 23 h kaklik /Designs/Measuring_instruments/AWS01A/SW/PIC16F887/ Diff
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/main.c
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/main.hex
/Designs/Measuring_instruments/AWS01A/SW/PIC16F887/main.pjt