←Prev12Next→ Show All
Rev Age Author Path Log message Diff Changes
3337 3907 d 8 h kaklik /Designs/ presunuti kodu vysokonapetoveho zdroje gm citace k vysokonapetovemu zdroji v laboratornich pristrojich. Diff
/Designs/Laboratory_instruments/High_voltage_power_supply/SW/PIC16F887
/Designs/Measuring_instruments/GM_counter/SW/HV_source
3322 3915 d 5 h kaklik /Designs/Measuring_instruments/GM_counter/DOC/SRC/img/ pridani obrazku umpulzu z GM trubice Diff
/Designs/Measuring_instruments/GM_counter/DOC/SRC/img
/Designs/Measuring_instruments/GM_counter/DOC/SRC/img/GM_impulse.png
3321 3915 d 5 h kaklik /Designs/Measuring_instruments/GM_counter/SW/HV_source/ osetreni spatneho zobrazeni nuloveho vystupu Diff
/Designs/Measuring_instruments/GM_counter/SW/HV_source/main.c
/Designs/Measuring_instruments/GM_counter/SW/HV_source/main.hex
3320 3915 d 6 h kaklik /Designs/Measuring_instruments/GM_counter/SW/HV_source/ osetreni hodnot mimo rozsah Diff
/Designs/Measuring_instruments/GM_counter/SW/HV_source/main.c
/Designs/Measuring_instruments/GM_counter/SW/HV_source/main.hex
3319 3915 d 6 h kaklik /Designs/Measuring_instruments/GM_counter/SW/HV_source/ nastavovani vystupu az do meznich hodnot Diff
/Designs/Measuring_instruments/GM_counter/SW/HV_source/main.c
/Designs/Measuring_instruments/GM_counter/SW/HV_source/main.hex
3318 3915 d 6 h kaklik /Designs/Measuring_instruments/GM_counter/SW/HV_source/ osetreni podteceni Diff
/Designs/Measuring_instruments/GM_counter/SW/HV_source/main.c
/Designs/Measuring_instruments/GM_counter/SW/HV_source/main.hex
3317 3915 d 6 h kaklik /Designs/Measuring_instruments/GM_counter/SW/HV_source/ osetreni preteceni Diff
/Designs/Measuring_instruments/GM_counter/SW/HV_source/main.c
/Designs/Measuring_instruments/GM_counter/SW/HV_source/main.hex
3316 3915 d 6 h kaklik /Designs/Measuring_instruments/GM_counter/SW/HV_source/ uprava rozsahu tlacitek Diff
/Designs/Measuring_instruments/GM_counter/SW/HV_source/main.c
/Designs/Measuring_instruments/GM_counter/SW/HV_source/main.hex
3315 3915 d 6 h kaklik /Designs/ zmena kalibrace Diff
/Designs/Laboratory_instruments/High_voltage_power_supply/DATA/fit.log
/Designs/Laboratory_instruments/High_voltage_power_supply/DATA/linearita.png
/Designs/Laboratory_instruments/High_voltage_power_supply/DATA/prevod.txt
/Designs/Measuring_instruments/GM_counter/SW/HV_source/main.c
/Designs/Measuring_instruments/GM_counter/SW/HV_source/main.hex
3313 3915 d 7 h kaklik /Designs/Measuring_instruments/GM_counter/SW/HV_source/ uprava zobrazeni Diff
/Designs/Measuring_instruments/GM_counter/SW/HV_source/main.c
/Designs/Measuring_instruments/GM_counter/SW/HV_source/main.hex
3312 3915 d 7 h kaklik /Designs/Measuring_instruments/GM_counter/SW/HV_source/ prepocet ADCu na realne napeti Diff
/Designs/Measuring_instruments/GM_counter/SW/HV_source/main.c
/Designs/Measuring_instruments/GM_counter/SW/HV_source/main.hex
3311 3915 d 7 h kaklik /Designs/Measuring_instruments/GM_counter/SW/HV_source/ nastartovani adc na zacatku behu programu Diff
/Designs/Measuring_instruments/GM_counter/SW/HV_source/main.c
/Designs/Measuring_instruments/GM_counter/SW/HV_source/main.hex
3310 3915 d 7 h kaklik /Designs/Measuring_instruments/GM_counter/SW/HV_source/ prevodnik se cte kontinuale v preruseni Diff
/Designs/Measuring_instruments/GM_counter/SW/HV_source/main.c
/Designs/Measuring_instruments/GM_counter/SW/HV_source/main.hex
3309 3915 d 7 h kaklik /Designs/Measuring_instruments/GM_counter/SW/HV_source/ eprava spoustoni ADC Diff
/Designs/Measuring_instruments/GM_counter/SW/HV_source/main.c
/Designs/Measuring_instruments/GM_counter/SW/HV_source/main.hex
3308 3915 d 7 h kaklik /Designs/Measuring_instruments/GM_counter/SW/HV_source/ presunuti cteni ADC a regulacni smycky do interruptu Diff
/Designs/Measuring_instruments/GM_counter/SW/HV_source/main.c
/Designs/Measuring_instruments/GM_counter/SW/HV_source/main.hex
3305 3915 d 8 h kaklik /Designs/Measuring_instruments/GM_counter/SW/HV_source/ zpomaleni hodin ADC Diff
/Designs/Measuring_instruments/GM_counter/SW/HV_source/main.c
/Designs/Measuring_instruments/GM_counter/SW/HV_source/main.hex
/Designs/Measuring_instruments/GM_counter/SW/HV_source/main.pjt
3304 3915 d 8 h kaklik /Designs/Measuring_instruments/GM_counter/SW/HV_source/ posunuti omezeni vystupu na vyssi hodnotu. Diff
/Designs/Measuring_instruments/GM_counter/SW/HV_source/main.c
/Designs/Measuring_instruments/GM_counter/SW/HV_source/main.hex
/Designs/Measuring_instruments/GM_counter/SW/HV_source/main.pjt
3302 3915 d 8 h kaklik /Designs/Measuring_instruments/GM_counter/SW/HV_source/ nastaveni externi reference a omozeni vystupnho napeti Diff
/Designs/Measuring_instruments/GM_counter/SW/HV_source/main.c
/Designs/Measuring_instruments/GM_counter/SW/HV_source/main.hex
/Designs/Measuring_instruments/GM_counter/SW/HV_source/main.pjt
3301 3915 d 9 h kaklik /Designs/Measuring_instruments/GM_counter/SW/HV_source/ Diff
/Designs/Measuring_instruments/GM_counter/SW/HV_source/main.c
/Designs/Measuring_instruments/GM_counter/SW/HV_source/main.hex
3300 3915 d 10 h kaklik /Designs/Measuring_instruments/GM_counter/SW/HV_source/ prelozeni hex pro zdroj Diff
/Designs/Measuring_instruments/GM_counter/SW/HV_source/main.hex