←Prev12Next→ Show All
Rev Age Author Path Log message Diff Changes
4744 2980 d 6 h kaklik /Modules/H_Bridge/HBSTEP01B/SW/ pridani noveho testu s vypisem statusu. Diff
/Modules/H_Bridge/HBSTEP01B/SW/I2CSPI_HBSTEP_status_test.py
4732 2982 d 20 h jacho / zmena Diff
/Modules/H_Bridge/HBSTEP01B/SW/I2CSPI_HBSTEP_SX17_test.py
/Designs/Laboratory_instruments/CLOCKMOT01A/CAD/CLOCKMOT01A_BOX01A/CAD/print_data/CLOCKMOT01A_BOX01A_kryt.scad
4724 2983 d 8 h kaklik /Modules/H_Bridge/HBSTEP01B/SW/ oprava chyby s adresovanim slovniku. Diff
/Modules/H_Bridge/HBSTEP01B/SW/I2CSPI_HBSTEP_test.py
4723 2984 d 1 h kaklik /Modules/H_Bridge/HBSTEP01B/SW/ kombinace zdrojovych kodu. Diff
/Modules/H_Bridge/HBSTEP01B/SW/DIRECT_SPI_HBSTEP_test.py
/Modules/H_Bridge/HBSTEP01B/SW/I2CSPI_HBSTEP_test.py
4722 2984 d 7 h kaklik /Modules/H_Bridge/HBSTEP01B/SW/ Upravy ke zvyseni kvality testovani pri primem pripojeni SPI. Diff
/Modules/H_Bridge/HBSTEP01B/SW/DIRECT_SPI_HBSTEP_test.py
4720 2984 d 7 h kaklik /Modules/H_Bridge/HBSTEP01B/SW/ omezena maximalni rychlost motoru. Diff
/Modules/H_Bridge/HBSTEP01B/SW/test.sh
4719 2984 d 21 h kaklik /Modules/H_Bridge/HBSTEP01B/SW/ dalsi testovaci funkce. Diff
/Modules/H_Bridge/HBSTEP01B/SW/I2CSPI_HBSTEP_test.py
4718 2985 d 1 h kaklik /Modules/H_Bridge/HBSTEP01B/SW/ sjednoceni metod v SPI a I2C zpusobu ovladani. Diff
/Modules/H_Bridge/HBSTEP01B/SW/I2CSPI_HBSTEP_SX17_test.py
/Modules/H_Bridge/HBSTEP01B/SW/DIRECT_SPI_HBSTEP_test.py
/Modules/H_Bridge/HBSTEP01B/SW/I2CSPI_HBSTEP_test.py
/Modules/H_Bridge/HBSTEP01B/SW/test.sh
4698 2990 d 9 h kaklik /Modules/H_Bridge/HBSTEP02A/SCH_PCB/ vygenerovano schema. Diff
/Modules/H_Bridge/HBSTEP02A/SCH_PCB/HBSTEP02A.pdf
4591 3107 d 21 h jacho /Modules/H_Bridge/HBSTEP01B/SW/ zmena Diff
/Modules/H_Bridge/HBSTEP01B/SW/I2CSPI_HBSTEP_SX17_test.py
4574 3124 d 4 h kaklik /Modules/H_Bridge/HBSTEP01B/SW/ zmena chovani na cyklicky test smeru otaceni motoru. Diff
/Modules/H_Bridge/HBSTEP01B/SW/DIRECT_SPI_HBSTEP_test.py
4573 3124 d 5 h kaklik /Modules/H_Bridge/HBSTEP01B/SW/ Uprava kodu tak, aby vstupni parametr pro rychlost byl zadavany ve steps/s Diff
/Modules/H_Bridge/HBSTEP01B/SW/DIRECT_SPI_HBSTEP_test.py
4570 3126 d 3 h kaklik /Modules/H_Bridge/HBSTEP01B/SW/ upravy kodu pro prime pripojeni odroidu. Diff
/Modules/H_Bridge/HBSTEP01B/SW/DIRECT_SPI_HBSTEP_test.py
4567 3127 d 20 h kaklik /Modules/H_Bridge/HBSTEP01B/SW/ oprava manipulace s listy. Diff
/Modules/H_Bridge/HBSTEP01B/SW/DIRECT_SPI_HBSTEP_test.py
4566 3127 d 21 h kaklik /Modules/H_Bridge/HBSTEP01B/SW/ oprava listu. Diff
/Modules/H_Bridge/HBSTEP01B/SW/DIRECT_SPI_HBSTEP_test.py
4565 3127 d 21 h kaklik /Modules/H_Bridge/HBSTEP01B/SW/ zmena parametru na list. Diff
/Modules/H_Bridge/HBSTEP01B/SW/DIRECT_SPI_HBSTEP_test.py
4563 3128 d 20 h kaklik /Modules/H_Bridge/HBSTEP01B/SW/ zmena nastaveni spi. Diff
/Modules/H_Bridge/HBSTEP01B/SW/DIRECT_SPI_HBSTEP_test.py
4561 3130 d 3 h kaklik /Modules/H_Bridge/HBSTEP01B/SW/ oprava adresace SPI rozhraní na ODROID-C1. Diff
/Modules/H_Bridge/HBSTEP01B/SW/DIRECT_SPI_HBSTEP_test.py
4557 3134 d 19 h kaklik /Modules/H_Bridge/HBSTEP01B/SW/ programovani testovaciho kodu pro prime pripojeni na SPI sbernici. Diff
/Modules/H_Bridge/HBSTEP01B/SW/DIRECT_SPI_HBSTEP_test.py
4552 3136 d 6 h jacho /Modules/ Diff
/Modules/ADconverters/I2CADC01A/DOC/SRC/img/I2CADC01A_top_big.jpg
/Modules/H_Bridge/HBSTEP01B/DOC/SRC/img/HBSTEP01B_Top_Big.jpg
/Modules/PowerSupply/LION2CELL01D/DOC/SRC/img/LION2CELL01D_Top_Big.jpg
/Modules/PowerSupply/LION2CELL01D/DOC/SRC/img/LION2CELL01D_Top_Big_back.jpg
/Modules/ADconverters/I2CADC01A/DOC/I2CADC01A.cs.pdf
/Modules/ADconverters/I2CADC01A/DOC/SRC/I2CADC01A.doc
/Modules/ADconverters/I2CADC01A/I2CADC01A_Small.jpg
/Modules/H_Bridge/HBSTEP01B/DOC/HBSTEP01B.cs.pdf
/Modules/H_Bridge/HBSTEP01B/DOC/SRC/HBSTEP01B.doc
/Modules/H_Bridge/HBSTEP01B/HBSTEP01B_Top_Small.jpg
/Modules/Mechanical/AWSCREEN01A/CAD/configuration.scad
/Modules/Mechanical/WINDGAUGE02A/CAD/configuration.scad
/Modules/PowerSupply/LION2CELL01D/DOC/LION2CELL01D.cs.pdf
/Modules/PowerSupply/LION2CELL01D/DOC/SRC/LION2CELL01D.docx
/Modules/PowerSupply/LION2CELL01D/LION2CELL01D_Small.jpg