←Prev12Next→ Show All
Rev Age Author Path Log message Diff Changes
2164 4667 d 10 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ uz funguje mereni teploty Diff
/Modules/TDC/GP201A/SW/PICinterface/main.c
/Modules/TDC/GP201A/SW/PICinterface/main.hex
/Modules/TDC/GP201A/SW/PICinterface/main.pjt
2163 4667 d 16 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ nefunguje mereni teploty spolecne s mericim modem 2 Diff
/Modules/TDC/GP201A/SW/PICinterface/GP2.c
/Modules/TDC/GP201A/SW/PICinterface/main.c
/Modules/TDC/GP201A/SW/PICinterface/main.hex
/Modules/TDC/GP201A/SW/PICinterface/main.pjt
2162 4668 d 5 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ verze s externim generatorem impulzu. Diff
/Modules/TDC/GP201A/SW/PICinterface/main.c
/Modules/TDC/GP201A/SW/PICinterface/main.hex
/Modules/TDC/GP201A/SW/PICinterface/main.pjt
2161 4668 d 6 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ Diff
/Modules/TDC/GP201A/SW/PICinterface/main.c
/Modules/TDC/GP201A/SW/PICinterface/main.hex
/Modules/TDC/GP201A/SW/PICinterface/main.pjt
2160 4668 d 6 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ vycisteni Diff
/Modules/TDC/GP201A/SW/PICinterface/main.c
/Modules/TDC/GP201A/SW/PICinterface/main.h
/Modules/TDC/GP201A/SW/PICinterface/main.hex
2159 4668 d 11 h kaklik / teplomer naportovan na novejsi PIC. Diff
/Designs/Thermometer/SW/PIC16F887
/Designs/Thermometer/SW/PIC16F887/main.c
/Designs/Thermometer/SW/PIC16F887/main.h
/Designs/Thermometer/SW/PIC16F887/main.hex
/Designs/Thermometer/SW/PIC16F887/main.pjt
/Modules/TDC/GP201A/PCB/GP2.pdf
/Designs/Thermometer/SW/main.c
/Designs/Thermometer/SW/main.h
/Designs/Thermometer/SW/main.hex
/Designs/Thermometer/SW/main.pjt
/Modules/TDC/GP201A/PCB/GP2.pcb
/Modules/TDC/GP201A/SW/PICinterface/main.c
/Modules/TDC/GP201A/SW/PICinterface/main.hex
2015 4757 d 7 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ Diff
/Modules/TDC/GP201A/SW/PICinterface/main.c
2014 4757 d 9 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ Diff
/Modules/TDC/GP201A/SW/PICinterface/main.c
2013 4757 d 15 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ drobne upravy Diff
/Modules/TDC/GP201A/SW/PICinterface/GP2.h
/Modules/TDC/GP201A/SW/PICinterface/main.c
/Modules/TDC/GP201A/SW/PICinterface/main.hex
/Modules/TDC/GP201A/SW/PICinterface/main.pjt
2012 4758 d 6 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ migrace na PIC16F887 Diff
/Modules/TDC/GP201A/SW/PICinterface/main.c
/Modules/TDC/GP201A/SW/PICinterface/main.h
/Modules/TDC/GP201A/SW/PICinterface/main.hex
/Modules/TDC/GP201A/SW/PICinterface/main.pjt
2011 4758 d 7 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ posledni verze pred prechodem na PIC16F887 Diff
/Modules/TDC/GP201A/SW/PICinterface/main.c
/Modules/TDC/GP201A/SW/PICinterface/main.hex
/Modules/TDC/GP201A/SW/PICinterface/main.pjt
1980 4786 d 13 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ pokus o zprovozneni mericiho modu 1.
V tomto stavu ale asi nefunguje ani mereni teploty.
Diff
/Modules/TDC/GP201A/SW/PICinterface/GP2.c
/Modules/TDC/GP201A/SW/PICinterface/main.c
/Modules/TDC/GP201A/SW/PICinterface/main.hex
1967 4792 d 6 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ oprava chyby ve vypoctu casu a implementace mereni teploty. Diff
/Modules/TDC/GP201A/SW/PICinterface/GP2.c
/Modules/TDC/GP201A/SW/PICinterface/main.c
/Modules/TDC/GP201A/SW/PICinterface/main.hex
1966 4792 d 6 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ prvni implementace prepoctu na realne jednotky. Diff
/Modules/TDC/GP201A/SW/PICinterface/GP2.c
/Modules/TDC/GP201A/SW/PICinterface/GP2.h
/Modules/TDC/GP201A/SW/PICinterface/main.c
/Modules/TDC/GP201A/SW/PICinterface/main.hex
1965 4792 d 9 h kaklik /Modules/TDC/GP201A/ implementace i posledni primitivy pro nastavovani registru Diff
/Modules/TDC/GP201A/DOC/datasheet.txt
/Modules/TDC/GP201A/SW/PICinterface/GP2.c
/Modules/TDC/GP201A/SW/PICinterface/main.c
/Modules/TDC/GP201A/SW/PICinterface/main.hex
/Modules/TDC/GP201A/SW/PICinterface/main.pjt
1964 4792 d 10 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ prepsani cteni dat do puvodnich primitiv. Diff
/Modules/TDC/GP201A/SW/PICinterface/GP2.c
/Modules/TDC/GP201A/SW/PICinterface/main.c
/Modules/TDC/GP201A/SW/PICinterface/main.hex
/Modules/TDC/GP201A/SW/PICinterface/main.pjt
1931 4811 d 6 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ testovani TDC Diff
/Modules/TDC/GP201A/SW/PICinterface/main.c
/Modules/TDC/GP201A/SW/PICinterface/main.hex
/Modules/TDC/GP201A/SW/PICinterface/main.pjt
1886 4849 d 6 h kakl /Modules/TDC/GP201A/SW/PICinterface/ Prvni verze, co neco meri. Diff
/Modules/TDC/GP201A/SW/PICinterface/main.c
/Modules/TDC/GP201A/SW/PICinterface/main.h
/Modules/TDC/GP201A/SW/PICinterface/main.hex
/Modules/TDC/GP201A/SW/PICinterface/main.pjt
1818 4875 d 14 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ vzmena IO nemela na funkci vliv. Diff
/Modules/TDC/GP201A/SW/PICinterface/main.c
/Modules/TDC/GP201A/SW/PICinterface/main.hex
/Modules/TDC/GP201A/SW/PICinterface/main.pjt
1817 4875 d 15 h kaklik /Modules/TDC/GP201A/SW/PICinterface/ Poslední pokus před výměnou IO. Diff
/Modules/TDC/GP201A/SW/PICinterface/main.c
/Modules/TDC/GP201A/SW/PICinterface/main.hex
/Modules/TDC/GP201A/SW/PICinterface/main.pjt