Rev Age Author Path Log message Diff Changes
4916 2534 d 7 h kaklik /Designs/Measuring_instruments/RSMS01A/ Novy detektor atmosferickych jevu. Diff
/Designs/Measuring_instruments/RSMS01A
/Designs/Measuring_instruments/RSMS01A/DOC
/Designs/Measuring_instruments/RSMS01A/DOC/SRC
/Designs/Measuring_instruments/RSMS01A/DOC/SRC/img
/Designs/Measuring_instruments/RSMS01A/DOC/SRC/img/RSMS_receiver.dia
/Designs/Measuring_instruments/RSMS01A/DOC/SRC/img/RSMS_receiver.png
/Designs/Measuring_instruments/RSMS01A/DOC/SRC/img/Signal_processig.dia
/Designs/Measuring_instruments/RSMS01A/HDL
/Designs/Measuring_instruments/RSMS01A/PrjInfo.txt
/Designs/Measuring_instruments/RSMS01A/SCH
/Designs/Measuring_instruments/RSMS01A/pdf
4915 2535 d 13 h jacho /Designs/Measuring_instruments/VLFMON01A/DOC/SRC/img/ Diff
/Designs/Measuring_instruments/VLFMON01A/DOC/SRC/img/antena.png
4914 2541 d 4 h jacho /Designs/Measuring_instruments/VLFMON01A/CAD/UNIBOX03A/CAD/ uprava celicek Diff
/Designs/Measuring_instruments/VLFMON01A/CAD/UNIBOX03A/CAD/AMF/panel1.stl
/Designs/Measuring_instruments/VLFMON01A/CAD/UNIBOX03A/CAD/AMF/panel2.stl
/Designs/Measuring_instruments/VLFMON01A/CAD/UNIBOX03A/CAD/panel1.scad
/Designs/Measuring_instruments/VLFMON01A/CAD/UNIBOX03A/CAD/panel2.scad
/Designs/Measuring_instruments/VLFMON01A/CAD/UNIBOX03A/CAD/src/otvory.scad
4913 2541 d 15 h jacho /Designs/Measuring_instruments/VLFMON01A/CAD/ CELICKA NA KRABICKU Diff
/Designs/Measuring_instruments/VLFMON01A/CAD
/Designs/Measuring_instruments/VLFMON01A/CAD/UNIBOX03A
/Designs/Measuring_instruments/VLFMON01A/CAD/UNIBOX03A/CAD
/Designs/Measuring_instruments/VLFMON01A/CAD/UNIBOX03A/CAD/AMF
/Designs/Measuring_instruments/VLFMON01A/CAD/UNIBOX03A/CAD/AMF/panel1.stl
/Designs/Measuring_instruments/VLFMON01A/CAD/UNIBOX03A/CAD/AMF/panel2.stl
/Designs/Measuring_instruments/VLFMON01A/CAD/UNIBOX03A/CAD/configuration.scad
/Designs/Measuring_instruments/VLFMON01A/CAD/UNIBOX03A/CAD/panel1.scad
/Designs/Measuring_instruments/VLFMON01A/CAD/UNIBOX03A/CAD/panel2.scad
/Designs/Measuring_instruments/VLFMON01A/CAD/UNIBOX03A/CAD/print_data
/Designs/Measuring_instruments/VLFMON01A/CAD/UNIBOX03A/CAD/src
/Designs/Measuring_instruments/VLFMON01A/CAD/UNIBOX03A/CAD/src/MLAB_logo.scad
/Designs/Measuring_instruments/VLFMON01A/CAD/UNIBOX03A/CAD/src/UNIBOX03A_D01.scad
/Designs/Measuring_instruments/VLFMON01A/CAD/UNIBOX03A/CAD/src/otvory.scad
/Designs/Measuring_instruments/VLFMON01A/CAD/UNIBOX03A/CAD/src/otvory_conf.scad
/Designs/Measuring_instruments/VLFMON01A/CAD/UNIBOX03A/PrjInfo.txt
4912 2592 d 8 h kaklik /Designs/Laboratory_instruments/ Presunuti dokumentace phmetru na github.
https://github.com/ODZ-UJF-AV-CR/pHmeter
Diff
/Designs/Laboratory_instruments/PHMET01A
4911 2634 d 7 h jacho /Designs/Measuring_instruments/VLFMON01A/PCB/VLFANT01B/DOC/SRC/img/ foto Diff
/Designs/Measuring_instruments/VLFMON01A/PCB/VLFANT01B/DOC/SRC/img/VLFANT01B_top_big.jpg
4910 2637 d 12 h kaklik /Designs/Measuring_instruments/ISMS01A/ Pridani navrhu podlozky pro podlozeni plastovych krabic s prevodniky. Diff
/Designs/Measuring_instruments/ISMS01A/AMF
/Designs/Measuring_instruments/ISMS01A/AMF/box_base.stl
/Designs/Measuring_instruments/ISMS01A/CAD
/Designs/Measuring_instruments/ISMS01A/CAD/box_base.scad
/Designs/Measuring_instruments/ISMS01A/CAD/small_panel.scad
4909 2638 d 7 h jacho /Designs/Laboratory_instruments/PDNCPU01A/SCH/ Diff
/Designs/Laboratory_instruments/PDNCPU01A/SCH
/Designs/Laboratory_instruments/PDNCPU01A/SCH/PDNCPU01A.dia
/Designs/Laboratory_instruments/PDNCPU01A/SCH/PDNCPU01A.png
4908 2646 d 8 h jacho /Designs/Laboratory_instruments/ vytvoreni novych zarizeni Diff
/Designs/Laboratory_instruments/PDNCPU01A
/Designs/Laboratory_instruments/PDNCPU01A/DOC
/Designs/Laboratory_instruments/PDNCPU01A/DOC/SRC
/Designs/Laboratory_instruments/PDNCPU01A/DOC/SRC/img
/Designs/Laboratory_instruments/PDNCPU01A/PrjInfo.txt
/Designs/Laboratory_instruments/PDNCPU01A/SW
/Designs/Laboratory_instruments/PDNI2CHUB01A
/Designs/Laboratory_instruments/PDNI2CHUB01A/DOC
/Designs/Laboratory_instruments/PDNI2CHUB01A/DOC/SRC
/Designs/Laboratory_instruments/PDNI2CHUB01A/DOC/SRC/img
/Designs/Laboratory_instruments/PDNI2CHUB01A/PrjInfo.txt
/Designs/Laboratory_instruments/PDNI2CHUB01A/SCH
/Designs/Laboratory_instruments/PDNI2CHUB01A/SCH/PDNI2CHUB01A.dia
/Designs/Laboratory_instruments/PDNI2CHUB01A/SCH/PDNI2CHUB01A.png
/Designs/Laboratory_instruments/PDNI2CHUB01A/SW
4907 2647 d 9 h kaklik /Designs/Measuring_instruments/RMDS02D/CAD/ Pismo zmeneno na vystoupnute. Pridan prechod mezi vertikalni a horizontalni casti drzaku. Diff
/Designs/Measuring_instruments/RMDS02D/CAD/connectors_holder.stl
/Designs/Measuring_instruments/RMDS02D/CAD/src/connectors_holder.scad