No changes between revisions
/Modules/H_Bridge/HBSTEP01B/SW/I2CSPI_HBSTEP_SX17_test.py |
---|
0,0 → 1,200 |
#!/usr/bin/python |
# ------------------------------------------- |
# HBSTEP01B Stepper Motor control test code |
# ------------------------------------------- |
# |
# Program uses MLAB Python modules library from https://github.com/MLAB-project/pymlab |
#uncomment for debbug purposes |
#import logging |
#logging.basicConfig(level=logging.DEBUG) |
import sys |
import time |
from pymlab import config |
#### Script Arguments ############################################### |
if len(sys.argv) < 2: |
sys.stderr.write("Invalid number of arguments.\n") |
sys.stderr.write("Usage: %s PORT ADDRESS SPEED MOVE_DISTANCE\n" % (sys.argv[0], )) |
sys.exit(1) |
elif len(sys.argv) == 2: |
PORT = eval(sys.argv[1]) |
SPEED = 5 |
DISTANCE = 50 |
elif len(sys.argv) == 3: |
SPEED = eval(sys.argv[2]) |
DISTANCE = 100 |
elif len(sys.argv) == 4: |
SPEED = eval(sys.argv[2]) |
DISTANCE = eval(sys.argv[3]) |
else: |
PORT = 0 |
SPEED = 10 |
DISTANCE = 50 |
class axis: |
def __init__(self, SPI_CS, Direction, StepsPerUnit): |
' One axis of robot ' |
self.CS = SPI_CS |
self.Dir = Direction |
self.SPU = StepsPerUnit |
self.Reset() |
def Reset(self): |
' Reset Axis and set default parameters for H-bridge ' |
spi.SPI_write_byte(self.CS, 0xC0) # reset |
# spi.SPI_write_byte(self.CS, 0x14) # Stall Treshold setup |
# spi.SPI_write_byte(self.CS, 0xFF) |
# spi.SPI_write_byte(self.CS, 0x13) # Over Current Treshold setup |
# spi.SPI_write_byte(self.CS, 0xFF) |
spi.SPI_write_byte(self.CS, 0x15) # Full Step speed |
spi.SPI_write_byte(self.CS, 0xFF) |
spi.SPI_write_byte(self.CS, 0xFF) |
spi.SPI_write_byte(self.CS, 0x05) # ACC |
spi.SPI_write_byte(self.CS, 0x00) |
spi.SPI_write_byte(self.CS, 0x10) |
spi.SPI_write_byte(self.CS, 0x06) # DEC |
spi.SPI_write_byte(self.CS, 0x00) |
spi.SPI_write_byte(self.CS, 0x10) |
spi.SPI_write_byte(self.CS, 0x0A) # KVAL_RUN |
spi.SPI_write_byte(self.CS, 0x1F) |
spi.SPI_write_byte(self.CS, 0x0B) # KVAL_ACC |
spi.SPI_write_byte(self.CS, 0x1F) |
spi.SPI_write_byte(self.CS, 0x0C) # KVAL_DEC |
spi.SPI_write_byte(self.CS, 0x1F) |
spi.SPI_write_byte(self.CS, 0x18) # CONFIG |
spi.SPI_write_byte(self.CS, 0b00111000) |
spi.SPI_write_byte(self.CS, 0b00000000) |
def MaxSpeed(self, speed): |
' Setup of maximum speed ' |
spi.SPI_write_byte(self.CS, 0x07) # Max Speed setup |
spi.SPI_write_byte(self.CS, 0x00) |
spi.SPI_write_byte(self.CS, speed) |
def ReleaseSW(self): |
' Go away from Limit Switch ' |
while self.ReadStatusBit(2) == 1: # is Limit Switch ON ? |
spi.SPI_write_byte(self.CS, 0x92 | (~self.Dir & 1)) # release SW |
while self.IsBusy(): |
pass |
self.MoveWait(10) # move 10 units away |
def GoZero(self, speed): |
' Go to Zero position ' |
self.ReleaseSW() |
spi.SPI_write_byte(self.CS, 0x82 | (self.Dir & 1)) # Go to Zero |
spi.SPI_write_byte(self.CS, 0x00) |
spi.SPI_write_byte(self.CS, speed) |
while self.IsBusy(): |
pass |
time.sleep(0.3) |
self.ReleaseSW() |
def Move(self, units): |
' Move some distance units from current position ' |
steps = units * self.SPU # translate units to steps |
if steps > 0: # look for direction |
spi.SPI_write_byte(self.CS, 0x40 | (~self.Dir & 1)) |
else: |
spi.SPI_write_byte(self.CS, 0x40 | (self.Dir & 1)) |
steps = int(abs(steps)) |
spi.SPI_write_byte(self.CS, (steps >> 16) & 0xFF) |
spi.SPI_write_byte(self.CS, (steps >> 8) & 0xFF) |
spi.SPI_write_byte(self.CS, steps & 0xFF) |
def MoveWait(self, units): |
' Move some distance units from current position and wait for execution ' |
self.Move(units) |
while self.IsBusy(): |
pass |
def Float(self): |
' switch H-bridge to High impedance state ' |
spi.SPI_write_byte(self.CS, 0xA0) |
def ReadStatusBit(self, bit): |
' Report given status bit ' |
spi.SPI_write_byte(self.CS, 0x39) # Read from address 0x19 (STATUS) |
spi.SPI_write_byte(self.CS, 0x00) |
data0 = spi.SPI_read_byte() # 1st byte |
spi.SPI_write_byte(self.CS, 0x00) |
data1 = spi.SPI_read_byte() # 2nd byte |
#print hex(data0), hex(data1) |
if bit > 7: # extract requested bit |
OutputBit = (data0 >> (bit - 8)) & 1 |
else: |
OutputBit = (data1 >> bit) & 1 |
return OutputBit |
def IsBusy(self): |
""" Return True if tehre are motion """ |
if self.ReadStatusBit(1) == 1: |
return False |
else: |
return True |
# End Class axis -------------------------------------------------- |
cfg = config.Config( |
i2c = { |
"port": 1, |
}, |
bus = [ |
{ |
"name":"spi", |
"type":"i2cspi", |
"address": 0x2e, |
}, |
], |
) |
cfg.initialize() |
print "Stepper motor control test started. \r\n" |
print "Max motor speed: %d " % SPEED |
print "Distance to run: %d " % DISTANCE |
spi = cfg.get_device("spi") |
spi.route() |
try: |
print "SPI configuration.." |
spi.SPI_config(spi.I2CSPI_MSB_FIRST| spi.I2CSPI_MODE_CLK_IDLE_HIGH_DATA_EDGE_TRAILING| spi.I2CSPI_CLK_461kHz) |
time.sleep(1) |
print "Axis inicialization" |
X = axis(spi.I2CSPI_SS0, 0, 641) # set Number of Steps per axis Unit and set Direction of Rotation |
X.MaxSpeed(SPEED) # set maximal motor speed |
print "Axis is running" |
for i in range(5): |
print i |
X.MoveWait(DISTANCE) # move forward and wait for motor stop |
print "Changing direction of rotation.." |
X.MoveWait(-DISTANCE) # move backward and wait for motor stop |
print "Changing direction of rotation.." |
X.Float() # release power |
finally: |
print "stop" |
Property changes: |
Added: svn:executable |
+* |
\ No newline at end of property |