Blame | Last modification | View Log
PADS Router 2005 SPac1, Routing report
Design: D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Wed Jun 21 21:08:06 2006
Autorouting D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Pre-routing analysis
Warning:Not enough vias for routing from the top to the bottom of the design.
To correct the problem, define additional vias or enable vias for routing using
the Via Biasing tab of the Design Properties dialog box.
==============================================================================================
Passes Processed: Route, Optimize
Routed Connections: 39(+39)
Vias: 0(+0)
Trace length: 18330(+18330) Mils
Test points: 0(+0)
Accessible nets: 0(+0)
Duration 00:00:07
==============================================================================================
Pass: 3 (Route)
Routed Connections: 39(+39)
Vias: 0(+0)
Trace length: 18456(+18456) Mils
Duration 00:00:02(+00:00:02)
==============================================================================================
Pass: 4 (Optimize)
Vias: 0(+0)
Trace length: 18330(-126) Mils
Rerouted: 0
Duration 00:00:07(+00:00:05)
==============================================================================================
Wed Jun 21 21:08:28 2006
Autorouting D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Pre-routing analysis
Warning:Not enough vias for routing from the top to the bottom of the design.
To correct the problem, define additional vias or enable vias for routing using
the Via Biasing tab of the Design Properties dialog box.
==============================================================================================
Passes Processed: Route, Optimize
Routed Connections: 39(+0)
Vias: 0(+0)
Trace length: 18239(-91) Mils
Test points: 0(+0)
Accessible nets: 0(+0)
Duration 00:00:05
==============================================================================================
Pass: 3 (Route)
Routed Connections: 39(+0)
Vias: 0(+0)
Trace length: 18330(+0) Mils
Duration 00:00:00(+00:00:00)
==============================================================================================
Pass: 4 (Optimize)
Vias: 0(+0)
Trace length: 18239(-91) Mils
Rerouted: 0
Duration 00:00:05(+00:00:04)
==============================================================================================
Wed Jun 21 21:08:58 2006
Autorouting D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Pre-routing analysis
Warning:Not enough vias for routing from the top to the bottom of the design.
To correct the problem, define additional vias or enable vias for routing using
the Via Biasing tab of the Design Properties dialog box.
==============================================================================================
Passes Processed: Route, Optimize
Routed Connections: 39(+4)
Vias: 0(+0)
Trace length: 18197(+1112) Mils
Test points: 0(+0)
Accessible nets: 0(+0)
Duration 00:00:05
==============================================================================================
Pass: 3 (Route)
Routed Connections: 39(+4)
Vias: 0(+0)
Trace length: 18286(+1201) Mils
Duration 00:00:01(+00:00:00)
==============================================================================================
Pass: 4 (Optimize)
Vias: 0(+0)
Trace length: 18197(-89) Mils
Rerouted: 0
Duration 00:00:05(+00:00:04)
==============================================================================================
Wed Jun 21 21:09:09 2006
Autorouting D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Pre-routing analysis
Warning:Not enough vias for routing from the top to the bottom of the design.
To correct the problem, define additional vias or enable vias for routing using
the Via Biasing tab of the Design Properties dialog box.
==============================================================================================
Passes Processed: Route, Optimize
Routed Connections: 39(+0)
Vias: 0(+0)
Trace length: 18197(+0) Mils
Test points: 0(+0)
Accessible nets: 0(+0)
Duration 00:00:05
==============================================================================================
Pass: 3 (Route)
Routed Connections: 39(+0)
Vias: 0(+0)
Trace length: 18197(+0) Mils
Duration 00:00:00(+00:00:00)
==============================================================================================
Pass: 4 (Optimize)
Vias: 0(+0)
Trace length: 18197(+0) Mils
Rerouted: 0
Duration 00:00:05(+00:00:04)
==============================================================================================
Wed Jun 21 21:10:07 2006
Autorouting D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Pre-routing analysis
Warning:Not enough vias for routing from the top to the bottom of the design.
To correct the problem, define additional vias or enable vias for routing using
the Via Biasing tab of the Design Properties dialog box.
==============================================================================================
Passes Processed: Route, Optimize
Routed Connections: 39(+7)
Vias: 0(+0)
Trace length: 17634(+3285) Mils
Test points: 0(+0)
Accessible nets: 0(+0)
Duration 00:00:06
==============================================================================================
Pass: 3 (Route)
Routed Connections: 39(+7)
Vias: 0(+0)
Trace length: 17653(+3304) Mils
Duration 00:00:01(+00:00:00)
==============================================================================================
Pass: 4 (Optimize)
Vias: 0(+0)
Trace length: 17634(-19) Mils
Rerouted: 0
Duration 00:00:06(+00:00:05)
==============================================================================================
Wed Jun 21 21:11:11 2006
Autorouting D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Pre-routing analysis
Warning:Not enough vias for routing from the top to the bottom of the design.
To correct the problem, define additional vias or enable vias for routing using
the Via Biasing tab of the Design Properties dialog box.
==============================================================================================
Passes Processed: Route, Optimize
Routed Connections: 39(+9)
Vias: 0(+0)
Trace length: 17264(+3659) Mils
Test points: 0(+0)
Accessible nets: 0(+0)
Duration 00:00:05
==============================================================================================
Pass: 3 (Route)
Routed Connections: 39(+9)
Vias: 0(+0)
Trace length: 17347(+3742) Mils
Duration 00:00:01(+00:00:00)
==============================================================================================
Pass: 4 (Optimize)
Vias: 0(+0)
Trace length: 17264(-83) Mils
Rerouted: 0
Duration 00:00:05(+00:00:04)
==============================================================================================
Wed Jun 21 21:11:18 2006
Autorouting D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Pre-routing analysis
Warning:Not enough vias for routing from the top to the bottom of the design.
To correct the problem, define additional vias or enable vias for routing using
the Via Biasing tab of the Design Properties dialog box.
==============================================================================================
Passes Processed: Route, Optimize
Routed Connections: 39(+0)
Vias: 0(+0)
Trace length: 17297(+33) Mils
Test points: 0(+0)
Accessible nets: 0(+0)
Duration 00:00:04
==============================================================================================
Pass: 3 (Route)
Routed Connections: 39(+0)
Vias: 0(+0)
Trace length: 17264(+0) Mils
Duration 00:00:00(+00:00:00)
==============================================================================================
Pass: 4 (Optimize)
Vias: 0(+0)
Trace length: 17297(+33) Mils
Rerouted: 0
Duration 00:00:04(+00:00:04)
==============================================================================================
Wed Jun 21 21:11:41 2006
Autorouting D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Pre-routing analysis
Warning:Not enough vias for routing from the top to the bottom of the design.
To correct the problem, define additional vias or enable vias for routing using
the Via Biasing tab of the Design Properties dialog box.
==============================================================================================
Passes Processed: Route, Optimize
Routed Connections: 38(+3)
Vias: 0(+0)
Trace length: 16203(+3778) Mils
Test points: 0(+0)
Accessible nets: 0(+0)
Duration 00:00:08
==============================================================================================
Pass: 3 (Route)
Routed Connections: 38(+3)
Vias: 0(+0)
Trace length: 16222(+3797) Mils
Duration 00:00:02(+00:00:02)
==============================================================================================
Pass: 4 (Optimize)
Vias: 0(+0)
Trace length: 16203(-19) Mils
Rerouted: 0
Duration 00:00:08(+00:00:06)
==============================================================================================
Wed Jun 21 21:11:50 2006
Autorouting D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Pre-routing analysis
Warning:Not enough vias for routing from the top to the bottom of the design.
To correct the problem, define additional vias or enable vias for routing using
the Via Biasing tab of the Design Properties dialog box.
==============================================================================================
Passes Processed: Route, Optimize
Routed Connections: 38(+0)
Vias: 0(+0)
Trace length: 16203(+0) Mils
Test points: 0(+0)
Accessible nets: 0(+0)
Duration 00:00:05
==============================================================================================
Pass: 3 (Route)
Routed Connections: 38(+0)
Vias: 0(+0)
Trace length: 16203(+0) Mils
Duration 00:00:01(+00:00:01)
==============================================================================================
Pass: 4 (Optimize)
Vias: 0(+0)
Trace length: 16203(+0) Mils
Rerouted: 0
Duration 00:00:05(+00:00:04)
==============================================================================================
Wed Jun 21 21:12:24 2006
Autorouting D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Pre-routing analysis
Warning:Not enough vias for routing from the top to the bottom of the design.
To correct the problem, define additional vias or enable vias for routing using
the Via Biasing tab of the Design Properties dialog box.
==============================================================================================
Passes Processed: Route, Optimize
Routed Connections: 39(+1)
Vias: 0(+0)
Trace length: 18010(+1245) Mils
Test points: 0(+0)
Accessible nets: 0(+0)
Duration 00:00:16
==============================================================================================
Pass: 3 (Route)
Routed Connections: 39(+1)
Vias: 0(+0)
Trace length: 18165(+1400) Mils
Duration 00:00:01(+00:00:00)
==============================================================================================
Pass: 4 (Optimize)
Vias: 0(+0)
Trace length: 18010(-155) Mils
Rerouted: 0
Duration 00:00:16(+00:00:15)
==============================================================================================
Wed Jun 21 21:12:54 2006
Autorouting D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Pre-routing analysis
Warning:Not enough vias for routing from the top to the bottom of the design.
To correct the problem, define additional vias or enable vias for routing using
the Via Biasing tab of the Design Properties dialog box.
==============================================================================================
Passes Processed: Route, Optimize
Routed Connections: 39(+0)
Vias: 0(+0)
Trace length: 17141(-129) Mils
Test points: 0(+0)
Accessible nets: 0(+0)
Duration 00:00:07
==============================================================================================
Pass: 3 (Route)
Routed Connections: 39(+0)
Vias: 0(+0)
Trace length: 17270(+0) Mils
Duration 00:00:00(+00:00:00)
==============================================================================================
Pass: 4 (Optimize)
Vias: 0(+0)
Trace length: 17141(-129) Mils
Rerouted: 0
Duration 00:00:07(+00:00:07)
==============================================================================================
Wed Jun 21 21:13:26 2006
Autorouting D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Pre-routing analysis
Warning:Not enough vias for routing from the top to the bottom of the design.
To correct the problem, define additional vias or enable vias for routing using
the Via Biasing tab of the Design Properties dialog box.
==============================================================================================
Passes Processed: Route, Optimize
Routed Connections: 38(+0)
Vias: 0(+0)
Trace length: 17100(+1) Mils
Test points: 0(+0)
Accessible nets: 0(+0)
Duration 00:00:04
==============================================================================================
Pass: 3 (Route)
Routed Connections: 38(+0)
Vias: 0(+0)
Trace length: 17099(+0) Mils
Duration 00:00:01(+00:00:01)
==============================================================================================
Pass: 4 (Optimize)
Vias: 0(+0)
Trace length: 17100(+1) Mils
Rerouted: 0
Duration 00:00:04(+00:00:03)
==============================================================================================
Wed Jun 21 21:13:49 2006
Autorouting D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Pre-routing analysis
Warning:Not enough vias for routing from the top to the bottom of the design.
To correct the problem, define additional vias or enable vias for routing using
the Via Biasing tab of the Design Properties dialog box.
==============================================================================================
Passes Processed: Route, Optimize
Routed Connections: 38(+0)
Vias: 0(+0)
Trace length: 17114(-81) Mils
Test points: 0(+0)
Accessible nets: 0(+0)
Duration 00:00:04
==============================================================================================
Pass: 3 (Route)
Routed Connections: 38(+0)
Vias: 0(+0)
Trace length: 17195(+0) Mils
Duration 00:00:01(+00:00:01)
==============================================================================================
Pass: 4 (Optimize)
Vias: 0(+0)
Trace length: 17114(-81) Mils
Rerouted: 0
Duration 00:00:04(+00:00:03)
==============================================================================================
Wed Jun 21 21:14:22 2006
Autorouting D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Pre-routing analysis
Warning:Not enough vias for routing from the top to the bottom of the design.
To correct the problem, define additional vias or enable vias for routing using
the Via Biasing tab of the Design Properties dialog box.
==============================================================================================
Passes Processed: Route, Optimize
Routed Connections: 39(+1)
Vias: 0(+0)
Trace length: 18523(+1285) Mils
Test points: 0(+0)
Accessible nets: 0(+0)
Duration 00:00:05
==============================================================================================
Pass: 3 (Route)
Routed Connections: 39(+1)
Vias: 0(+0)
Trace length: 19299(+2061) Mils
Duration 00:00:01(+00:00:00)
==============================================================================================
Pass: 4 (Optimize)
Vias: 0(+0)
Trace length: 18523(-776) Mils
Rerouted: 0
Duration 00:00:05(+00:00:04)
==============================================================================================
Wed Jun 21 21:14:28 2006
Autorouting D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Pre-routing analysis
Warning:Not enough vias for routing from the top to the bottom of the design.
To correct the problem, define additional vias or enable vias for routing using
the Via Biasing tab of the Design Properties dialog box.
==============================================================================================
Passes Processed: Route, Optimize
Routed Connections: 39(+0)
Vias: 0(+0)
Trace length: 18523(+0) Mils
Test points: 0(+0)
Accessible nets: 0(+0)
Duration 00:00:04
==============================================================================================
Pass: 3 (Route)
Routed Connections: 39(+0)
Vias: 0(+0)
Trace length: 18523(+0) Mils
Duration 00:00:00(+00:00:00)
==============================================================================================
Pass: 4 (Optimize)
Vias: 0(+0)
Trace length: 18523(+0) Mils
Rerouted: 0
Duration 00:00:04(+00:00:03)
==============================================================================================
Wed Jun 21 21:15:23 2006
Autorouting D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Pre-routing analysis
Warning:Not enough vias for routing from the top to the bottom of the design.
To correct the problem, define additional vias or enable vias for routing using
the Via Biasing tab of the Design Properties dialog box.
==============================================================================================
Passes Processed: Route, Optimize
Routed Connections: 39(+11)
Vias: 0(+0)
Trace length: 16987(+4341) Mils
Test points: 0(+0)
Accessible nets: 0(+0)
Duration 00:00:05
==============================================================================================
Pass: 3 (Route)
Routed Connections: 39(+11)
Vias: 0(+0)
Trace length: 17038(+4392) Mils
Duration 00:00:01(+00:00:00)
==============================================================================================
Pass: 4 (Optimize)
Vias: 0(+0)
Trace length: 16987(-51) Mils
Rerouted: 0
Duration 00:00:05(+00:00:04)
==============================================================================================
Wed Jun 21 21:15:30 2006
Autorouting D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Pre-routing analysis
Warning:Not enough vias for routing from the top to the bottom of the design.
To correct the problem, define additional vias or enable vias for routing using
the Via Biasing tab of the Design Properties dialog box.
==============================================================================================
Passes Processed: Route, Optimize
Routed Connections: 39(+0)
Vias: 0(+0)
Trace length: 16987(+0) Mils
Test points: 0(+0)
Accessible nets: 0(+0)
Duration 00:00:05
==============================================================================================
Pass: 3 (Route)
Routed Connections: 39(+0)
Vias: 0(+0)
Trace length: 16987(+0) Mils
Duration 00:00:00(+00:00:00)
==============================================================================================
Pass: 4 (Optimize)
Vias: 0(+0)
Trace length: 16987(+0) Mils
Rerouted: 0
Duration 00:00:05(+00:00:04)
==============================================================================================
Wed Jun 21 21:15:37 2006
Autorouting D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Pre-routing analysis
Warning:Not enough vias for routing from the top to the bottom of the design.
To correct the problem, define additional vias or enable vias for routing using
the Via Biasing tab of the Design Properties dialog box.
==============================================================================================
Passes Processed: Route, Optimize
Routed Connections: 39(+0)
Vias: 0(+0)
Trace length: 16987(+0) Mils
Test points: 0(+0)
Accessible nets: 0(+0)
Duration 00:00:05
==============================================================================================
Pass: 3 (Route)
Routed Connections: 39(+0)
Vias: 0(+0)
Trace length: 16987(+0) Mils
Duration 00:00:00(+00:00:00)
==============================================================================================
Pass: 4 (Optimize)
Vias: 0(+0)
Trace length: 16987(+0) Mils
Rerouted: 0
Duration 00:00:05(+00:00:04)
==============================================================================================
Wed Jun 21 21:15:44 2006
Autorouting D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Pre-routing analysis
Warning:Not enough vias for routing from the top to the bottom of the design.
To correct the problem, define additional vias or enable vias for routing using
the Via Biasing tab of the Design Properties dialog box.
==============================================================================================
Passes Processed: Route, Optimize
Routed Connections: 39(+0)
Vias: 0(+0)
Trace length: 16987(+0) Mils
Test points: 0(+0)
Accessible nets: 0(+0)
Duration 00:00:05
==============================================================================================
Pass: 3 (Route)
Routed Connections: 39(+0)
Vias: 0(+0)
Trace length: 16987(+0) Mils
Duration 00:00:00(+00:00:00)
==============================================================================================
Pass: 4 (Optimize)
Vias: 0(+0)
Trace length: 16987(+0) Mils
Rerouted: 0
Duration 00:00:05(+00:00:04)
==============================================================================================
Wed Jun 21 21:26:09 2006
Autorouting D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Pre-routing analysis
Warning:Not enough vias for routing from the top to the bottom of the design.
To correct the problem, define additional vias or enable vias for routing using
the Via Biasing tab of the Design Properties dialog box.
==============================================================================================
Passes Processed: Route, Optimize
Routed Connections: 39(+4)
Vias: 0(+0)
Trace length: 17122(+1362) Mils
Test points: 0(+0)
Accessible nets: 0(+0)
Duration 00:00:05
==============================================================================================
Pass: 3 (Route)
Routed Connections: 39(+4)
Vias: 0(+0)
Trace length: 17122(+1362) Mils
Duration 00:00:01(+00:00:00)
==============================================================================================
Pass: 4 (Optimize)
Vias: 0(+0)
Trace length: 17122(+0) Mils
Rerouted: 0
Duration 00:00:05(+00:00:04)
==============================================================================================
Wed Jun 21 21:26:16 2006
Autorouting D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Pre-routing analysis
Warning:Not enough vias for routing from the top to the bottom of the design.
To correct the problem, define additional vias or enable vias for routing using
the Via Biasing tab of the Design Properties dialog box.
==============================================================================================
Passes Processed: Route, Optimize
Routed Connections: 39(+0)
Vias: 0(+0)
Trace length: 17122(+0) Mils
Test points: 0(+0)
Accessible nets: 0(+0)
Duration 00:00:05
==============================================================================================
Pass: 3 (Route)
Routed Connections: 39(+0)
Vias: 0(+0)
Trace length: 17122(+0) Mils
Duration 00:00:00(+00:00:00)
==============================================================================================
Pass: 4 (Optimize)
Vias: 0(+0)
Trace length: 17122(+0) Mils
Rerouted: 0
Duration 00:00:05(+00:00:04)
==============================================================================================
Wed Jun 21 21:26:35 2006
Autorouting D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Pre-routing analysis
Warning:Not enough vias for routing from the top to the bottom of the design.
To correct the problem, define additional vias or enable vias for routing using
the Via Biasing tab of the Design Properties dialog box.
==============================================================================================
Passes Processed: Route, Optimize
Routed Connections: 39(+2)
Vias: 0(+0)
Trace length: 17143(+747) Mils
Test points: 0(+0)
Accessible nets: 0(+0)
Duration 00:00:05
==============================================================================================
Pass: 3 (Route)
Routed Connections: 39(+2)
Vias: 0(+0)
Trace length: 17158(+762) Mils
Duration 00:00:00(+00:00:00)
==============================================================================================
Pass: 4 (Optimize)
Vias: 0(+0)
Trace length: 17143(-15) Mils
Rerouted: 0
Duration 00:00:05(+00:00:04)
==============================================================================================
Wed Jun 21 21:26:42 2006
Autorouting D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Pre-routing analysis
Warning:Not enough vias for routing from the top to the bottom of the design.
To correct the problem, define additional vias or enable vias for routing using
the Via Biasing tab of the Design Properties dialog box.
==============================================================================================
Passes Processed: Route, Optimize
Routed Connections: 39(+0)
Vias: 0(+0)
Trace length: 17143(+0) Mils
Test points: 0(+0)
Accessible nets: 0(+0)
Duration 00:00:05
==============================================================================================
Pass: 3 (Route)
Routed Connections: 39(+0)
Vias: 0(+0)
Trace length: 17143(+0) Mils
Duration 00:00:00(+00:00:00)
==============================================================================================
Pass: 4 (Optimize)
Vias: 0(+0)
Trace length: 17143(+0) Mils
Rerouted: 0
Duration 00:00:05(+00:00:04)
==============================================================================================
Wed Jun 21 21:28:12 2006
Autorouting D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Pre-routing analysis
Warning:Not enough vias for routing from the top to the bottom of the design.
To correct the problem, define additional vias or enable vias for routing using
the Via Biasing tab of the Design Properties dialog box.
==============================================================================================
Passes Processed: Route, Optimize
Routed Connections: 39(+6)
Vias: 0(+0)
Trace length: 18223(+3788) Mils
Test points: 0(+0)
Accessible nets: 0(+0)
Duration 00:00:04
==============================================================================================
Pass: 3 (Route)
Routed Connections: 39(+6)
Vias: 0(+0)
Trace length: 18232(+3797) Mils
Duration 00:00:01(+00:00:01)
==============================================================================================
Pass: 4 (Optimize)
Vias: 0(+0)
Trace length: 18223(-9) Mils
Rerouted: 0
Duration 00:00:04(+00:00:02)
==============================================================================================
Wed Jun 21 21:28:17 2006
Autorouting D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Pre-routing analysis
Warning:Not enough vias for routing from the top to the bottom of the design.
To correct the problem, define additional vias or enable vias for routing using
the Via Biasing tab of the Design Properties dialog box.
==============================================================================================
Passes Processed: Route, Optimize
Routed Connections: 39(+0)
Vias: 0(+0)
Trace length: 18027(-196) Mils
Test points: 0(+0)
Accessible nets: 0(+0)
Duration 00:00:04
==============================================================================================
Pass: 3 (Route)
Routed Connections: 39(+0)
Vias: 0(+0)
Trace length: 18223(+0) Mils
Duration 00:00:00(+00:00:00)
==============================================================================================
Pass: 4 (Optimize)
Vias: 0(+0)
Trace length: 18027(-196) Mils
Rerouted: 0
Duration 00:00:03(+00:00:03)
==============================================================================================
Wed Jun 21 21:28:47 2006
Autorouting D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Pre-routing analysis
Warning:Not enough vias for routing from the top to the bottom of the design.
To correct the problem, define additional vias or enable vias for routing using
the Via Biasing tab of the Design Properties dialog box.
==============================================================================================
Passes Processed: Route, Optimize
Routed Connections: 39(+39)
Vias: 0(+0)
Trace length: 18066(+18066) Mils
Test points: 0(+0)
Accessible nets: 0(+0)
Duration 00:00:08
==============================================================================================
Pass: 3 (Route)
Routed Connections: 39(+39)
Vias: 0(+0)
Trace length: 18165(+18165) Mils
Duration 00:00:03(+00:00:02)
==============================================================================================
Pass: 4 (Optimize)
Vias: 0(+0)
Trace length: 18066(-99) Mils
Rerouted: 0
Duration 00:00:08(+00:00:05)
==============================================================================================
Wed Jun 21 21:35:48 2006
Autorouting D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Pre-routing analysis
Warning:Not enough vias for routing from the top to the bottom of the design.
To correct the problem, define additional vias or enable vias for routing using
the Via Biasing tab of the Design Properties dialog box.
==============================================================================================
Passes Processed: Route, Optimize
Routed Connections: 39(+3)
Vias: 0(+0)
Trace length: 17526(+1871) Mils
Test points: 0(+0)
Accessible nets: 0(+0)
Duration 00:00:08
==============================================================================================
Pass: 3 (Route)
Routed Connections: 39(+3)
Vias: 0(+0)
Trace length: 17492(+1837) Mils
Duration 00:00:01(+00:00:01)
==============================================================================================
Pass: 4 (Optimize)
Vias: 0(+0)
Trace length: 17526(+34) Mils
Rerouted: 0
Duration 00:00:08(+00:00:07)
==============================================================================================
Wed Jun 21 21:36:04 2006
Autorouting D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Pre-routing analysis
Warning:Not enough vias for routing from the top to the bottom of the design.
To correct the problem, define additional vias or enable vias for routing using
the Via Biasing tab of the Design Properties dialog box.
==============================================================================================
Passes Processed: Route, Optimize
Routed Connections: 39(+0)
Vias: 0(+0)
Trace length: 17526(+0) Mils
Test points: 0(+0)
Accessible nets: 0(+0)
Duration 00:00:06
==============================================================================================
Pass: 3 (Route)
Routed Connections: 39(+0)
Vias: 0(+0)
Trace length: 17526(+0) Mils
Duration 00:00:00(+00:00:00)
==============================================================================================
Pass: 4 (Optimize)
Vias: 0(+0)
Trace length: 17526(+0) Mils
Rerouted: 0
Duration 00:00:06(+00:00:06)
==============================================================================================
Wed Jun 21 21:37:07 2006
Autorouting D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Pre-routing analysis
Warning:Not enough vias for routing from the top to the bottom of the design.
To correct the problem, define additional vias or enable vias for routing using
the Via Biasing tab of the Design Properties dialog box.
==============================================================================================
Passes Processed: Route, Optimize
Routed Connections: 39(+4)
Vias: 0(+0)
Trace length: 18099(+2886) Mils
Test points: 0(+0)
Accessible nets: 0(+0)
Duration 00:00:04
==============================================================================================
Pass: 3 (Route)
Routed Connections: 39(+4)
Vias: 0(+0)
Trace length: 18403(+3190) Mils
Duration 00:00:01(+00:00:01)
==============================================================================================
Pass: 4 (Optimize)
Vias: 0(+0)
Trace length: 18099(-304) Mils
Rerouted: 0
Duration 00:00:04(+00:00:03)
==============================================================================================
Wed Jun 21 21:38:08 2006
Autorouting D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Pre-routing analysis
Warning:Not enough vias for routing from the top to the bottom of the design.
To correct the problem, define additional vias or enable vias for routing using
the Via Biasing tab of the Design Properties dialog box.
==============================================================================================
Passes Processed: Route, Optimize
Routed Connections: 39(+7)
Vias: 0(+0)
Trace length: 17550(+2325) Mils
Test points: 0(+0)
Accessible nets: 0(+0)
Duration 00:00:07
==============================================================================================
Pass: 3 (Route)
Routed Connections: 39(+7)
Vias: 0(+0)
Trace length: 17712(+2487) Mils
Duration 00:00:01(+00:00:01)
==============================================================================================
Pass: 4 (Optimize)
Vias: 0(+0)
Trace length: 17550(-162) Mils
Rerouted: 0
Duration 00:00:07(+00:00:06)
==============================================================================================
Wed Jun 21 21:38:15 2006
Autorouting D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Pre-routing analysis
Warning:Not enough vias for routing from the top to the bottom of the design.
To correct the problem, define additional vias or enable vias for routing using
the Via Biasing tab of the Design Properties dialog box.
==============================================================================================
Passes Processed: Route, Optimize
Routed Connections: 39(+0)
Vias: 0(+0)
Trace length: 17550(+0) Mils
Test points: 0(+0)
Accessible nets: 0(+0)
Duration 00:00:06
==============================================================================================
Pass: 3 (Route)
Routed Connections: 39(+0)
Vias: 0(+0)
Trace length: 17550(+0) Mils
Duration 00:00:00(+00:00:00)
==============================================================================================
Pass: 4 (Optimize)
Vias: 0(+0)
Trace length: 17550(+0) Mils
Rerouted: 0
Duration 00:00:06(+00:00:06)
==============================================================================================
Wed Jun 21 21:39:28 2006
Autorouting D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Pre-routing analysis
Warning:Not enough vias for routing from the top to the bottom of the design.
To correct the problem, define additional vias or enable vias for routing using
the Via Biasing tab of the Design Properties dialog box.
==============================================================================================
Passes Processed: Route, Optimize
Routed Connections: 39(+0)
Vias: 0(+0)
Trace length: 17550(+0) Mils
Test points: 0(+0)
Accessible nets: 0(+0)
Duration 00:00:06
==============================================================================================
Pass: 3 (Route)
Routed Connections: 39(+0)
Vias: 0(+0)
Trace length: 17550(+0) Mils
Duration 00:00:00(+00:00:00)
==============================================================================================
Pass: 4 (Optimize)
Vias: 0(+0)
Trace length: 17550(+0) Mils
Rerouted: 0
Duration 00:00:06(+00:00:06)
==============================================================================================
Wed Jun 21 21:41:21 2006
Autorouting D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Pre-routing analysis
Warning:Not enough vias for routing from the top to the bottom of the design.
To correct the problem, define additional vias or enable vias for routing using
the Via Biasing tab of the Design Properties dialog box.
==============================================================================================
Passes Processed: Route, Optimize
Routed Connections: 39(+10)
Vias: 0(+0)
Trace length: 17178(+2753) Mils
Test points: 0(+0)
Accessible nets: 0(+0)
Duration 00:00:06
==============================================================================================
Pass: 3 (Route)
Routed Connections: 39(+10)
Vias: 0(+0)
Trace length: 17250(+2825) Mils
Duration 00:00:01(+00:00:00)
==============================================================================================
Pass: 4 (Optimize)
Vias: 0(+0)
Trace length: 17178(-72) Mils
Rerouted: 0
Duration 00:00:06(+00:00:06)
==============================================================================================
Wed Jun 21 21:41:31 2006
Autorouting D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Pre-routing analysis
Warning:Not enough vias for routing from the top to the bottom of the design.
To correct the problem, define additional vias or enable vias for routing using
the Via Biasing tab of the Design Properties dialog box.
==============================================================================================
Passes Processed: Route, Optimize
Routed Connections: 39(+0)
Vias: 0(+0)
Trace length: 17178(+0) Mils
Test points: 0(+0)
Accessible nets: 0(+0)
Duration 00:00:06
==============================================================================================
Pass: 3 (Route)
Routed Connections: 39(+0)
Vias: 0(+0)
Trace length: 17178(+0) Mils
Duration 00:00:00(+00:00:00)
==============================================================================================
Pass: 4 (Optimize)
Vias: 0(+0)
Trace length: 17178(+0) Mils
Rerouted: 0
Duration 00:00:06(+00:00:05)
==============================================================================================
Wed Jun 21 21:42:14 2006
Autorouting D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Pre-routing analysis
Warning:Not enough vias for routing from the top to the bottom of the design.
To correct the problem, define additional vias or enable vias for routing using
the Via Biasing tab of the Design Properties dialog box.
==============================================================================================
Passes Processed: Route, Optimize
Routed Connections: 39(+2)
Vias: 0(+0)
Trace length: 17146(+430) Mils
Test points: 0(+0)
Accessible nets: 0(+0)
Duration 00:00:06
==============================================================================================
Pass: 3 (Route)
Routed Connections: 39(+2)
Vias: 0(+0)
Trace length: 17146(+430) Mils
Duration 00:00:01(+00:00:00)
==============================================================================================
Pass: 4 (Optimize)
Vias: 0(+0)
Trace length: 17146(+0) Mils
Rerouted: 0
Duration 00:00:06(+00:00:05)
==============================================================================================
Wed Jun 21 21:42:25 2006
Autorouting D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Passes Processed: Route, Optimize
Routed Connections: 39(+10)
Vias: 0(+0)
Trace length: 16965(+2836) Mils
Test points: 0(+0)
Accessible nets: 0(+0)
Duration 00:00:03
==============================================================================================
Pass: 3 (Route)
Routed Connections: 39(+10)
Vias: 0(+0)
Trace length: 16980(+2851) Mils
Duration 00:00:01(+00:00:01)
==============================================================================================
Pass: 4 (Optimize)
Vias: 0(+0)
Trace length: 16965(-15) Mils
Rerouted: 0
Duration 00:00:02(+00:00:01)
==============================================================================================
Wed Jun 21 21:42:34 2006
Autorouting D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Pre-routing analysis
Warning:Not enough vias for routing from the top to the bottom of the design.
To correct the problem, define additional vias or enable vias for routing using
the Via Biasing tab of the Design Properties dialog box.
==============================================================================================
Passes Processed: Route, Optimize
Routed Connections: 39(+0)
Vias: 0(+0)
Trace length: 16965(+0) Mils
Test points: 0(+0)
Accessible nets: 0(+0)
Duration 00:00:05
==============================================================================================
Pass: 3 (Route)
Routed Connections: 39(+0)
Vias: 0(+0)
Trace length: 16965(+0) Mils
Duration 00:00:00(+00:00:00)
==============================================================================================
Pass: 4 (Optimize)
Vias: 0(+0)
Trace length: 16965(+0) Mils
Rerouted: 0
Duration 00:00:04(+00:00:04)
==============================================================================================
Wed Jun 21 21:42:58 2006
Autorouting D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Pre-routing analysis
Warning:Not enough vias for routing from the top to the bottom of the design.
To correct the problem, define additional vias or enable vias for routing using
the Via Biasing tab of the Design Properties dialog box.
==============================================================================================
Passes Processed: Route, Optimize
Routed Connections: 39(+4)
Vias: 0(+0)
Trace length: 18810(+5337) Mils
Test points: 0(+0)
Accessible nets: 0(+0)
Duration 00:00:07
==============================================================================================
Pass: 3 (Route)
Routed Connections: 39(+4)
Vias: 0(+0)
Trace length: 18862(+5389) Mils
Duration 00:00:01(+00:00:01)
==============================================================================================
Pass: 4 (Optimize)
Vias: 0(+0)
Trace length: 18810(-52) Mils
Rerouted: 0
Duration 00:00:07(+00:00:05)
==============================================================================================
Wed Jun 21 21:43:08 2006
Autorouting D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Pre-routing analysis
Warning:Not enough vias for routing from the top to the bottom of the design.
To correct the problem, define additional vias or enable vias for routing using
the Via Biasing tab of the Design Properties dialog box.
==============================================================================================
Passes Processed: Route, Optimize
Routed Connections: 39(+0)
Vias: 0(+0)
Trace length: 18810(+0) Mils
Test points: 0(+0)
Accessible nets: 0(+0)
Duration 00:00:05
==============================================================================================
Pass: 3 (Route)
Routed Connections: 39(+0)
Vias: 0(+0)
Trace length: 18810(+0) Mils
Duration 00:00:00(+00:00:00)
==============================================================================================
Pass: 4 (Optimize)
Vias: 0(+0)
Trace length: 18810(+0) Mils
Rerouted: 0
Duration 00:00:05(+00:00:05)
==============================================================================================
Wed Jun 21 21:44:18 2006
Autorouting D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Pre-routing analysis
Warning:Not enough vias for routing from the top to the bottom of the design.
To correct the problem, define additional vias or enable vias for routing using
the Via Biasing tab of the Design Properties dialog box.
==============================================================================================
Passes Processed: Route, Optimize
Routed Connections: 39(+3)
Vias: 0(+0)
Trace length: 18825(+1125) Mils
Test points: 0(+0)
Accessible nets: 0(+0)
Duration 00:00:06
==============================================================================================
Pass: 3 (Route)
Routed Connections: 39(+3)
Vias: 0(+0)
Trace length: 18825(+1125) Mils
Duration 00:00:01(+00:00:00)
==============================================================================================
Pass: 4 (Optimize)
Vias: 0(+0)
Trace length: 18825(+0) Mils
Rerouted: 0
Duration 00:00:05(+00:00:05)
==============================================================================================
Wed Jun 21 21:45:11 2006
Autorouting D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Pre-routing analysis
Warning:Not enough vias for routing from the top to the bottom of the design.
To correct the problem, define additional vias or enable vias for routing using
the Via Biasing tab of the Design Properties dialog box.
==============================================================================================
Passes Processed: Route, Optimize
Routed Connections: 39(+0)
Vias: 0(+0)
Trace length: 18825(+0) Mils
Test points: 0(+0)
Accessible nets: 0(+0)
Duration 00:00:05
==============================================================================================
Pass: 3 (Route)
Routed Connections: 39(+0)
Vias: 0(+0)
Trace length: 18825(+0) Mils
Duration 00:00:00(+00:00:00)
==============================================================================================
Pass: 4 (Optimize)
Vias: 0(+0)
Trace length: 18825(+0) Mils
Rerouted: 0
Duration 00:00:05(+00:00:05)
==============================================================================================
Wed Jun 21 21:46:32 2006
Autorouting D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Pre-routing analysis
Warning:Not enough vias for routing from the top to the bottom of the design.
To correct the problem, define additional vias or enable vias for routing using
the Via Biasing tab of the Design Properties dialog box.
==============================================================================================
Passes Processed: Route, Optimize
Routed Connections: 39(+5)
Vias: 0(+0)
Trace length: 18804(+1048) Mils
Test points: 0(+0)
Accessible nets: 0(+0)
Duration 00:00:06
==============================================================================================
Pass: 3 (Route)
Routed Connections: 39(+5)
Vias: 0(+0)
Trace length: 18824(+1068) Mils
Duration 00:00:01(+00:00:00)
==============================================================================================
Pass: 4 (Optimize)
Vias: 0(+0)
Trace length: 18804(-20) Mils
Rerouted: 0
Duration 00:00:06(+00:00:05)
==============================================================================================
Wed Jun 21 21:47:06 2006
Autorouting D:\KAKLIK\schemata\default_blz1.pcb
==============================================================================================
Pre-routing analysis
Warning:Not enough vias for routing from the top to the bottom of the design.
To correct the problem, define additional vias or enable vias for routing using
the Via Biasing tab of the Design Properties dialog box.
==============================================================================================
Passes Processed: Route, Optimize
Routed Connections: 39(+0)
Vias: 0(+0)
Trace length: 18804(+0) Mils
Test points: 0(+0)
Accessible nets: 0(+0)
Duration 00:00:05
==============================================================================================
Pass: 3 (Route)
Routed Connections: 39(+0)
Vias: 0(+0)
Trace length: 18804(+0) Mils
Duration 00:00:00(+00:00:00)
==============================================================================================
Pass: 4 (Optimize)
Vias: 0(+0)
Trace length: 18804(+0) Mils
Rerouted: 0
Duration 00:00:05(+00:00:05)
==============================================================================================